18L Portable Stainless Steel High Pressure Steam Medical Autoclave Sterilizer CE
The product uses saturated steam to rapidly and efficiently sterilize articles. It can be used in hospitals, public health centers, health stations, clinics in factories and mines, scientific research institutes, etc, to sterilize medical equipment, surgical dressings, glass utensils, solutions, substrata. It can also be used as cooker in plateau areas and be used to make high quality drinking water in industrial and mining enterprises.
Features:
1. Fully stainless steel structure.
2. Hand wheel type of quick-open door structure.
3. Digital display of working status,touch type key.
4. Automatically shut off with beep reminding after sterilization.
5. Electric heated.
6. Easy to operate,safe and reliable.
7. With pressure steam adjuster, when pressure reached the setting value, it’ll keep and control.
8. With timer, when the time reached the setting, auto turn off power and alarm to tell sterilize end.
9. With safety valve, release valve and gauge, when the steam pressure go over 0.165Mpa, the release valve should exhaust the pressure to ensure the safety, there is reading on the gauge face for both Mpa and temperature for check the data.
10. With electric heating elements of immerge type, auto pressure control and water lack protection.
11. The container and drum adopted stainless steel 0Gr18Ni9Ti, anti-acid, anti-alkali and anti-rust.
12. SKU: BJ-D-18HDD-110 BJ-D-18HDD-220
Specifications:
Sterilizing volume: 18L
Working pressure: 0.14-0.16MPa
Working temperature: 126℃
Temperature adjust range: 105-126℃
Timer range: 0-99 min
Max. safety pressure:0.165Mpa
Heat average:≤±1℃
Power:AC220V.110V 50Hz / 2KW
Dimension:410×410×630 mm
G.W / N. W:14/12 KG
Safety and maintenance:
1. This sterilizer is steam pressure vessel so do not impact in using and forbid overpressure. If the pressure pointer of pressure gauge reaches the 0.165MPa and the safety valve does not exhaust, it should stop using at once and check up the safety valve.
2. The pointer should be at zero position before usage the pressure gauge, otherwise the gauge has been failure and it should repair or replace the gauge. The pressure gauge should be regulated 1~2 times per year, ensuring sensitiveness and correctness.
3. Drain the water inside the container and condensing water below the sieve plate and had better wipe out water and deposit on the electro-thermal tube in order to benefit the sterilization quality and prolong the working life.
4. Gasket is easy to wear. If it does not wok well, see it whether become aging and hard, then replace it in time.
Autoclave Sterilizer Dental Supplies Dental Equipment