.png)
FEATURES
1. 4 new technology
Multi-protection safety lock
Wide liquid crystal screen
Steam compensation techniques
Doublestage tandem type vacuum pump
2. Japan vacuum pump
Noise is less than 60db, vacuum pump can highly reach -0.8KG/cm2, vacuum pumping efficiency is 30% higher than similar sterilizer.
3. Italian CEME liquid pump
4. Italian CEME valve body
5. PARKER valve body
6. Three times pulsation vacuum, the final vacuum can be up to -0.85bar, which ensure the air can be evacuated efficiently and achieve to saturated-vapor state. Thus the steam can completely permeate into the article with lace fabrics, hollow appliances (like handpiece) and packing articles, which is very important to sterilizing.
7. The humidity after Vacuum drying is less than 0.2%. The pulsing work equipped with double series vacuum pump when in the process of whole pulsing.
8. Separate steam generation technology, appliances are safer, disinfection are faster. Combines the steam compensation technique, ensure the 134 degreen moist heat sterlization as required by appliance.
9. Preset 8 concrete programs are listed according to their actual frequency of use. And what's more, added a hemophilus inactivation program.
10. Automatic door open and close system.
11. Fully automatic operation, the whole process computer self check and monitor.
12. Disintection process self evaluation system.
Advantages
1. LCD display, 8 programs Automaticly feeding water and draining water system easy to operate.
2. Full-Automatical operation, check and monitor by computer
3. Printer inside, note the sterilization process in details
4. Automatic and safety door lock system
5. Have an enaluation system of sterilization process
6. According to Europer B standard, with 3 times pre-vacuum
7. The water setting is full-automatic
8. Can show the reason of failure on LCD, do not need to check recording to code menu
9. Over heat control: When inner temperature is overheated, power will be shut down automatically and alarm system
10. Over pressure control: It have alarm system when over pressure.
11. Safety door lock system
12. Low water level indictor: It have alarm system when low water
Technical Data
Power supply: 230VAC ± 10% 50HZ/10A
Power: Max 1200VA
Dimensions of complete machine: W475*H410*D480mm
Chamber dimensions(mm): 250*280mm
Packing size: 630*600*500mm
Minimun desk size: 480*350mm
Net weight:37.5kg
Gross weight:45.5kg
Sterilize temperature:121℃/134℃
Control type: Full automatic microprocessor
Bacteria filter: Standard
Appliance tray: Stand 3 tayers
Printer: Matching
Operation enviroment: +2-40 indoor operation
Max relative humidity: 85%
Care and Maintenance:
Disinfect and clean the inside of the sterilizer with medical alcohol every month.
Change the fuse, when the fuse is bad, you must turn off the power first, and then change the fuse.
Clean the seal termly: You should clean the seal termly, to prevent the impurity, and improve sealability. If the sealability is bad, you should debus the seal and clean it. If the seal is bad, you must change it in time.
Change the seal:
a) When the seal is invalidation, you should change it in time. You may nip the border of the seal and take off it.
b)Clean the trough of fixing seal.
C). Kindly press the new seal into the trough of fixing seal till it enter completely. Don't use the knife-edge to stick or press the seal, such as screwdrever, knife and so on.
Transportation and storage:
1) The preparative of transportation and storage: Turn off the power, pull out the power plug, and cool the sterilizer.
2) The condition of transportation and storage: Circumstance temperature:-20℃-+55℃, relative humidity:<85%